Tamma Shouri
TAMMAHOMES · Rangareddy · RERA P02400008022
TAMMA SHOURI is a residential apartment building in Madhava Hills, Serilingampally Mandal, Ranga Reddy District. The registered promoter developing it is TAMMAHOMES. The project occupies 334.39 sq. m and comprises one building of 1 Stilt + 5 upper floors, with 10 2BHK homes, each with a RERA-filed saleable area of 121.0 sq. m. Its TG-RERA registration number is P02400008022, and the header records a proposed completion date of 28/05/2027.
01What we found
Read from TG-RERA filings, approvals, land and registration records and court records. A court case is counted only when the court record states this project's survey number with its village, or names the project.
02Check before you pay
10 items to check before you pay, 3 high - from the title chain, court records and approvals, each with what to ask the builder or your advocate. An item may not be a problem with the project: records can be incomplete.
1. Project at a glance
Project identity
| Field | RERA-filed / recorded information |
|---|---|
| Registered project name | TAMMA SHOURI RERA record |
| Project type | Residential apartment building RERA record RERA filing |
| Phase / registered portion | No phase name or separate phase identifier disclosed; the registration concerns the project at Survey No. 218/3. RERA record |
| TG-RERA registration | P02400008022 RERA record |
| Registration validity | 8 April 2024 to 28 January 2027, unless extended by the Authority. This is the registration period, not the construction deadline. RERA record |
| Registered promoter | TAMMAHOMES (also shown in project documents as TAMMA HOMES); organization type recorded as Proprietorship. RERA record RERA filing Corporate record |
| RERA status | RERA record identifies the project as New Project. RERA record RERA filing |
Land and geographic identity
| Field | RERA-filed / recorded information |
|---|---|
| Locality | Madhava Hills; the approval-plan description specifies Madhava Hills, Phase-II, Kondapur. RERA record RERA filing |
| Revenue village | Kondapur Village RERA record RERA filing |
| Mandal | Serilingampally RERA record RERA filing |
| District | Ranga Reddy RERA record RERA filing |
| PIN | 500084 RERA record RERA filing |
| Project survey number(s) | Survey No. 218/3; no project subdivision is stated in the supplied project filing. RERA record RERA filing Land records |
| Site extent | 334.39 sq. m; sanctioned-plan record states plot area and net plot area are each 334.39 sq. m, with road-affected and nala-affected area each 0.0 sq. m. Land records |
| Boundaries | North, south, east and west boundaries are recorded as NA in the supplied land details. Land records |
Development identity
| Field | RERA-filed / sanctioned information |
|---|---|
| Sanctioning authority | Greater Hyderabad Municipal Corporation (GHMC) Approvals record |
| Principal building approval | Building Permit Order 5383/GHMC/SLP/2024-BP, approved 28 January 2024; file no. 011611/GHMC/5719/SLP2/2023-BP. Approvals record |
| Layout / proceeding references on plan | 6/MP2/H/01; the plan also prints municipal reference G/177/L.P/426/96-97, dated 27/09/2023. Approvals record |
| Approved built-up area | GHMC permit records 916.85 sq. m residential area excluding parking and 1,084.45 sq. m including parking; the layout-plan extraction separately lists TOTAL BUA 1099.28 and NET BUA 916.85. These are the figures as labelled in the respective supplied records. |
| Building count and sanctioned floors | One proposed residential building: 1 Stilt + 5 upper floors. RERA filing |
| Height | The permit extraction lists Height of the Building 14.9; the layout-plan extraction lists Excluding Stilt Floor 14.90 mt., 17.88 mt. from GL, and Total Ht. 21.88mt. |
| Parking provision | Permit record lists Total Parking Area 167.6 (sq. m); the layout-plan record lists PARKING AREA 167.60. No parking-space count is supplied. |
| Unit count | 10 dwelling units in the sanctioned-plan extraction; RERA unit record also lists 10 units. RERA unit table |
Offering and status
| Field | RERA-filed / recorded information |
|---|---|
| Configuration | 2BHK, 10 units RERA unit table RERA unit details |
| RERA-filed saleable area | 121.0 sq. m per 2BHK configuration RERA unit table RERA unit details |
| Booked / available | 0 booked / 10 available in the portal-derived unit record; no as-of date is supplied, so these counts are indicative. RERA unit table RERA unit details |
| Construction stage | No construction-progress percentage or independently verified site-status record is supplied. RERA record RERA amenities |
| Completion dates | RERA Form B declares completion by 28-01-2027; the RERA registration certificate states validity to 28/01/2027. The header separately records a proposed completion date of 28/05/2027. These fields are reproduced as recorded; the completion-date detail should be checked in the relevant project documents and approval record. RERA record |
| Occupancy / completion certificate | No occupancy or completion certificate is supplied; the building permit makes an occupancy certificate a condition before occupation and before release for registration of the mortgaged built-up area. |
2. The project story
TAMMA SHOURI is recorded with TG-RERA as a residential apartment project on a 334.39 sq. m site in Survey No. 218/3, Kondapur Village, Serilingampally Mandal, Ranga Reddy District. The GHMC permit describes one proposed building of 1 Stilt + 5 upper floors, with 10 dwelling units; the RERA unit schedule records ten 2BHK homes. RERA record Land records RERA unit table
The RERA record shows the project as a new project, but the supplied evidence does not establish its present construction stage or independently verify progress at the site. The promoter’s Form B contains a completion undertaking of 28-01-2027. The supplied permit and RERA certificate also refer to completion / registration timing, while no occupancy or completion certificate is included. RERA record
3. Master plan, architecture & building design
The supplied GHMC plan and permit describe a single residential building on Survey No. 218/3, with a sanctioned configuration of 1 Stilt + 5 upper floors. The permit extraction lists 916.85 sq. m residential area and 171.21 sq. m for the stilt; the plan extraction records 916.85 sq. m net BUA, 1,084.45 sq. m total proposed built-up area including parking, and 1099.28 as total BUA. These are distinct figures as labelled in the extracted records, not interchangeable measures.
The plan records a vacant plot area of 151.02 sq. m, parking area of 167.60 sq. m, and building setbacks shown in the permit as front 3.04, rear 2, side I 2, and side II 2. The supplied materials do not provide a verified floor-by-floor apartment arrangement, number of flats per floor, lift or stair details, building footprint, or open-space area.
The building permit includes plan conditions concerning, among other matters, maintaining setbacks, use of stilt/cellar parking only for parking, and obtaining approval for modifications. Details of the permit conditions and their application are addressed in the approvals review.
4. Homes, configurations & floor plans
The TG-RERA unit record lists 10 2BHK units, with a RERA-filed saleable area of 121.0 sq. m per unit. The available count is 10 and booked count 0, but the portal-derived record has no as-of date. RERA unit table RERA unit details
| Configuration | Units | Booked | Available | RERA saleable area | Measured carpet area | Loading (if supplied) |
|---|---|---|---|---|---|---|
| 2BHK | 10 | 0 | 10 | 121.0 sq. m | Software-measured range: 72.3–89.5 sq. m; median 81.4 sq. m | 33% |
The carpet-area figures are software measurements from the approved floor-plan drawing geometry, not RERA-filed disclosures, and are flagged as needing review. The supplied measurement covers four flat designs. Carpet area represents the measured internal floor area; the RERA saleable area is a separate filed figure and includes the home’s share of common areas. The supplied data does not provide a verified unit-specific balcony, utility or loading breakdown. Floor plans RERA unit details
5. Parking & vehicle circulation
The sanctioned-plan record provides 167.60 sq. m of parking area. The building is sanctioned with a stilt level, and the permit states that the stilt/cellar areas approved for parking must be used exclusively for vehicle parking. No count of car or two-wheeler spaces, visitor or accessible bays, mechanical parking, vehicle-ramp arrangement, EV-charger count, or unit-wise parking allocation is supplied. A plan reference to parking does not, by itself, establish exclusive parking rights for a particular unit.
6. Amenities, recreation & open spaces
The RERA amenities record lists project facilities and services, but all supplied progress percentages are 0; the record therefore does not establish that any listed facility has been completed or independently verified. The plan and permit also identify certain site provisions. RERA amenities
| Description / size | Size not supplied; the plan refers to a tot-lot and peripheral greenery. |
|---|---|
| Evidence source | RERA amenities |
| Declared progress / verified status | RERA progress recorded as 0%; not independently verified complete. |
| Description / size | No source or capacity supplied in the RERA amenities record. |
|---|---|
| Evidence source | RERA amenities |
| Declared progress / verified status | Listed available as “YES”; progress recorded as 0%; completion not independently verified. |
| Description / size | RERA record lists sewerage including chamber, lines, septic tank and STP; no capacity supplied. |
|---|---|
| Evidence source | RERA amenities Promoter website |
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
| Description / size | Details and capacity not supplied. |
|---|---|
| Evidence source | RERA amenities |
| Declared progress / verified status | Progress recorded as 0%; not independently verified complete. |
| Description / size | Permit requires a garbage house within the premises; no size supplied. |
|---|---|
| Evidence source | RERA amenities |
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
| Description / size | Permit refers to rainwater-harvesting structures; the permit extraction lists 2 pits. |
|---|---|
| Evidence source | RERA amenities |
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
| Description / size | No system details supplied. |
|---|---|
| Evidence source | RERA amenities |
| Declared progress / verified status | Listed available as “YES”; progress recorded as 0%; not independently verified complete. |
| Description / size | Permit specifies fire-fighting installations; no system capacity or completion evidence supplied. |
|---|---|
| Evidence source | RERA amenities |
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
| Description / size | Permit specifies space for a transformer; no capacity supplied. |
|---|---|
| Evidence source | RERA amenities |
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
7. Utilities, building services & safety
The supplied plan and permit identify water supply, electricity connections, a transformer space, rainwater harvesting, a garbage house, a generator, emergency lighting, and fire-fighting installations. The plan extraction specifies an underground static water-storage tank of 25,000 litres, a terrace tank of 25,000 litres, and an overhead water tank of 22,000 LTS. These are plan-recorded provisions; evidence of installation, operation or commissioning is not supplied.
The RERA amenities record lists sewerage, storm-water drainage, sewage/sullage treatment and disposal, solid-waste management, water conservation/rainwater harvesting, energy management and fire protection. The vendor record separately lists an STP, power backup, 24-hour water supply and security; these are vendor-described facilities, not evidence of completion. No supplied record gives STP capacity, water source, electrical backup capacity, lift count or capacity, CCTV installation status, accessibility details or an occupancy/fire clearance. RERA amenities Promoter website
8. Location, access & connectivity
The registered location is Madhava Hills, Kondapur, in Kondapur Village, Serilingampally Mandal, Ranga Reddy District, Telangana 500084. The approval-plan description further identifies Madhava Hills, Phase-II. RERA record RERA filing
The supplied location record gives HITEC City — 5.4 km as a connectivity distance. The plan records references to an 18 mt. road width and a 12.0M WIDE ROAD, but the supplied data does not identify a verified project approach route or public-transport service. Location record
9. Developer & development status
The registered promoter is TAMMAHOMES, recorded as a Proprietorship; project approval and declaration documents also use the name TAMMA HOMES and identify proprietor TAMMA MATHI REDDY. The RERA certificate lists the promoter’s registered office as Kukatpally, Kukatpally Mandal, Medchal-Malkajgiri District, PIN 500085. Project contact details and an official website are not supplied. Corporate record RERA filing
The supplied record identifies a single proposed building and no separately identified development phase. The promoter’s Form B declares completion by 28-01-2027; no construction-progress certification or occupancy/completion certificate is included in the supplied evidence.
10. Approvals, official records & documents
| Identifier / date | P02400008022; validity stated as 08/04/2024–28/01/2027 |
|---|---|
| Supplied evidence | Form C registration certificate |
| Identifier / date | 5383/GHMC/SLP/2024-BP, approved 28 January 2024; file no. 011611/GHMC/5719/SLP2/2023-BP |
|---|---|
| Supplied evidence | Building Permit Order for the proposed residential building |
| Identifier / date | 6/MP2/H/01; plan also prints G/177/L.P/426/96-97, dated 27/09/2023 |
|---|---|
| Supplied evidence | GHMC plan material filed with the project |
| Identifier / date | Dated 5 MARCH 2026 |
|---|---|
| Supplied evidence | Promoter declaration, including its stated title basis, encumbrance declaration, and completion undertaking |
| Identifier / date | Layout reference 338615/LP/GP/205278/0001/2023 |
|---|---|
| Supplied evidence | Supplied letter identifies Survey No. 218/3 and extent 334.39 SQ MT; plot number and approval authority are unfilled in the extracted record. |
| Identifier / date | Not supplied |
|---|---|
| Supplied evidence | Permit states an occupancy certificate is required before occupation; no certificate is included. |
1. Project at a glance
Project identity
Registered project name: TAMMA SHOURI
Project type: Residential apartment building
Phase / registered portion: No phase name or separate phase identifier disclosed; the registration concerns the project at Survey No. 218/3.
TG-RERA registration: P02400008022
Registration validity: 8 April 2024 to 28 January 2027, unless extended by the Authority. This is the registration period, not the construction deadline.
Registered promoter: TAMMAHOMES (also shown in project documents as TAMMA HOMES); organization type recorded as Proprietorship.
RERA status: RERA record identifies the project as New Project.
Land and geographic identity
Locality: Madhava Hills; the approval-plan description specifies Madhava Hills, Phase-II, Kondapur.
Revenue village: Kondapur Village
Mandal: Serilingampally
District: Ranga Reddy
PIN: 500084
Project survey number(s): Survey No. 218/3; no project subdivision is stated in the supplied project filing.
Site extent: 334.39 sq. m; sanctioned-plan record states plot area and net plot area are each 334.39 sq. m, with road-affected and nala-affected area each 0.0 sq. m.
Boundaries: North, south, east and west boundaries are recorded as NA in the supplied land details.
Development identity
Sanctioning authority: Greater Hyderabad Municipal Corporation (GHMC)
Principal building approval: Building Permit Order 5383/GHMC/SLP/2024-BP, approved 28 January 2024; file no. 011611/GHMC/5719/SLP2/2023-BP.
Layout / proceeding references on plan: 6/MP2/H/01; the plan also prints municipal reference G/177/L.P/426/96-97, dated 27/09/2023.
Approved built-up area: GHMC permit records 916.85 sq. m residential area excluding parking and 1,084.45 sq. m including parking; the layout-plan extraction separately lists TOTAL BUA 1099.28 and NET BUA 916.85. These are the figures as labelled in the respective supplied records.
Building count and sanctioned floors: One proposed residential building: 1 Stilt + 5 upper floors.
Height: The permit extraction lists Height of the Building 14.9; the layout-plan extraction lists Excluding Stilt Floor 14.90 mt., 17.88 mt. from GL, and Total Ht. 21.88mt.
Parking provision: Permit record lists Total Parking Area 167.6 (sq. m); the layout-plan record lists PARKING AREA 167.60. No parking-space count is supplied.
Unit count: 10 dwelling units in the sanctioned-plan extraction; RERA unit record also lists 10 units.
Offering and status
Configuration: 2BHK, 10 units
RERA-filed saleable area: 121.0 sq. m per 2BHK configuration
Booked / available: 0 booked / 10 available in the portal-derived unit record; no as-of date is supplied, so these counts are indicative.
Construction stage: No construction-progress percentage or independently verified site-status record is supplied.
Completion dates: RERA Form B declares completion by 28-01-2027; the RERA registration certificate states validity to 28/01/2027. The header separately records a proposed completion date of 28/05/2027. These fields are reproduced as recorded; the completion-date detail should be checked in the relevant project documents and approval record.
Occupancy / completion certificate: No occupancy or completion certificate is supplied; the building permit makes an occupancy certificate a condition before occupation and before release for registration of the mortgaged built-up area.
2. The project story
TAMMA SHOURI is recorded with TG-RERA as a residential apartment project on a 334.39 sq. m site in Survey No. 218/3, Kondapur Village, Serilingampally Mandal, Ranga Reddy District. The GHMC permit describes one proposed building of 1 Stilt + 5 upper floors, with 10 dwelling units; the RERA unit schedule records ten 2BHK homes.
The RERA record shows the project as a new project, but the supplied evidence does not establish its present construction stage or independently verify progress at the site. The promoter’s Form B contains a completion undertaking of 28-01-2027. The supplied permit and RERA certificate also refer to completion / registration timing, while no occupancy or completion certificate is included.
3. Master plan, architecture & building design
The supplied GHMC plan and permit describe a single residential building on Survey No. 218/3, with a sanctioned configuration of 1 Stilt + 5 upper floors. The permit extraction lists 916.85 sq. m residential area and 171.21 sq. m for the stilt; the plan extraction records 916.85 sq. m net BUA, 1,084.45 sq. m total proposed built-up area including parking, and 1099.28 as total BUA. These are distinct figures as labelled in the extracted records, not interchangeable measures.
The plan records a vacant plot area of 151.02 sq. m, parking area of 167.60 sq. m, and building setbacks shown in the permit as front 3.04, rear 2, side I 2, and side II 2. The supplied materials do not provide a verified floor-by-floor apartment arrangement, number of flats per floor, lift or stair details, building footprint, or open-space area.
The building permit includes plan conditions concerning, among other matters, maintaining setbacks, use of stilt/cellar parking only for parking, and obtaining approval for modifications. Details of the permit conditions and their application are addressed in the approvals review.
4. Homes, configurations & floor plans
The TG-RERA unit record lists 10 2BHK units, with a RERA-filed saleable area of 121.0 sq. m per unit. The available count is 10 and booked count 0, but the portal-derived record has no as-of date.
| Configuration | Units | Booked | Available | RERA saleable area | Measured carpet area | Loading (if supplied) |
|---|---|---|---|---|---|---|
| 2BHK | 10 | 0 | 10 | 121.0 sq. m | Software-measured range: 72.3–89.5 sq. m; median 81.4 sq. m | 33% |
The carpet-area figures are software measurements from the approved floor-plan drawing geometry, not RERA-filed disclosures, and are flagged as needing review. The supplied measurement covers four flat designs. Carpet area represents the measured internal floor area; the RERA saleable area is a separate filed figure and includes the home’s share of common areas. The supplied data does not provide a verified unit-specific balcony, utility or loading breakdown.
5. Parking & vehicle circulation
The sanctioned-plan record provides 167.60 sq. m of parking area. The building is sanctioned with a stilt level, and the permit states that the stilt/cellar areas approved for parking must be used exclusively for vehicle parking. No count of car or two-wheeler spaces, visitor or accessible bays, mechanical parking, vehicle-ramp arrangement, EV-charger count, or unit-wise parking allocation is supplied. A plan reference to parking does not, by itself, establish exclusive parking rights for a particular unit.
6. Amenities, recreation & open spaces
The RERA amenities record lists project facilities and services, but all supplied progress percentages are 0; the record therefore does not establish that any listed facility has been completed or independently verified. The plan and permit also identify certain site provisions.
| Description / size | Size not supplied; the plan refers to a tot-lot and peripheral greenery. |
|---|---|
| Declared progress / verified status | RERA progress recorded as 0%; not independently verified complete. |
| Description / size | No source or capacity supplied in the RERA amenities record. |
|---|---|
| Declared progress / verified status | Listed available as “YES”; progress recorded as 0%; completion not independently verified. |
| Description / size | RERA record lists sewerage including chamber, lines, septic tank and STP; no capacity supplied. |
|---|---|
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
| Description / size | Details and capacity not supplied. |
|---|---|
| Declared progress / verified status | Progress recorded as 0%; not independently verified complete. |
| Description / size | Permit requires a garbage house within the premises; no size supplied. |
|---|---|
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
| Description / size | Permit refers to rainwater-harvesting structures; the permit extraction lists 2 pits. |
|---|---|
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
| Description / size | No system details supplied. |
|---|---|
| Declared progress / verified status | Listed available as “YES”; progress recorded as 0%; not independently verified complete. |
| Description / size | Permit specifies fire-fighting installations; no system capacity or completion evidence supplied. |
|---|---|
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
| Description / size | Permit specifies space for a transformer; no capacity supplied. |
|---|---|
| Declared progress / verified status | RERA-listed; progress recorded as 0%; not independently verified complete. |
7. Utilities, building services & safety
The supplied plan and permit identify water supply, electricity connections, a transformer space, rainwater harvesting, a garbage house, a generator, emergency lighting, and fire-fighting installations. The plan extraction specifies an underground static water-storage tank of 25,000 litres, a terrace tank of 25,000 litres, and an overhead water tank of 22,000 LTS. These are plan-recorded provisions; evidence of installation, operation or commissioning is not supplied.
The RERA amenities record lists sewerage, storm-water drainage, sewage/sullage treatment and disposal, solid-waste management, water conservation/rainwater harvesting, energy management and fire protection. The vendor record separately lists an STP, power backup, 24-hour water supply and security; these are vendor-described facilities, not evidence of completion. No supplied record gives STP capacity, water source, electrical backup capacity, lift count or capacity, CCTV installation status, accessibility details or an occupancy/fire clearance.
8. Location, access & connectivity
The registered location is Madhava Hills, Kondapur, in Kondapur Village, Serilingampally Mandal, Ranga Reddy District, Telangana 500084. The approval-plan description further identifies Madhava Hills, Phase-II.
The supplied location record gives HITEC City — 5.4 km as a connectivity distance. The plan records references to an 18 mt. road width and a 12.0M WIDE ROAD, but the supplied data does not identify a verified project approach route or public-transport service.
9. Developer & development status
The registered promoter is TAMMAHOMES, recorded as a Proprietorship; project approval and declaration documents also use the name TAMMA HOMES and identify proprietor TAMMA MATHI REDDY. The RERA certificate lists the promoter’s registered office as Kukatpally, Kukatpally Mandal, Medchal-Malkajgiri District, PIN 500085. Project contact details and an official website are not supplied.
The supplied record identifies a single proposed building and no separately identified development phase. The promoter’s Form B declares completion by 28-01-2027; no construction-progress certification or occupancy/completion certificate is included in the supplied evidence.
10. Approvals, official records & documents
| Identifier / date | P02400008022; validity stated as 08/04/2024–28/01/2027 |
|---|---|
| Supplied evidence | Form C registration certificate |
| Identifier / date | 5383/GHMC/SLP/2024-BP, approved 28 January 2024; file no. 011611/GHMC/5719/SLP2/2023-BP |
|---|---|
| Supplied evidence | Building Permit Order for the proposed residential building |
| Identifier / date | 6/MP2/H/01; plan also prints G/177/L.P/426/96-97, dated 27/09/2023 |
|---|---|
| Supplied evidence | GHMC plan material filed with the project |
| Identifier / date | Dated 5 MARCH 2026 |
|---|---|
| Supplied evidence | Promoter declaration, including its stated title basis, encumbrance declaration, and completion undertaking |
| Identifier / date | Layout reference 338615/LP/GP/205278/0001/2023 |
|---|---|
| Supplied evidence | Supplied letter identifies Survey No. 218/3 and extent 334.39 SQ MT; plot number and approval authority are unfilled in the extracted record. |
| Identifier / date | Not supplied |
|---|---|
| Supplied evidence | Permit states an occupancy certificate is required before occupation; no certificate is included. |
Frequently asked questions
Is TAMMA SHOURI registered with Telangana RERA?
Yes. TAMMA SHOURI is registered with the Telangana Real Estate Regulatory Authority as P02400008022; the registration status is New Project.
Who is the developer of TAMMA SHOURI?
The promoter named in the RERA registration is TAMMAHOMES.
Where is TAMMA SHOURI located?
TAMMA SHOURI is in MADHAVA HILLS, Kondapur, Serilingampally, Rangareddy, Telangana (500084).
When will TAMMA SHOURI be completed?
The promoter's proposed date of completion filed with RERA is 28/05/2027. This is the promoter's declaration, not a guarantee.